Radix Electrosystems Private Limited
Radix Electrosystems Private Limited
Airoli, Navi Mumbai, Thane, Maharashtra
GST No. 27AAACR0436Q1Z4
TrustSEAL Verified
Call 0804860005261% Response Rate
SEND EMAIL

Sanitary RTD Sensors

Providing you the best range of sanitary rtd without protection sheath-rhs70 series, sanitary rtd sensors with tri clover connection, sanitary rtd sensors with ingold port, sanitary rtd sensors with female nut and flameproof rtd sensors - with sanitary fittings with effective & timely delivery.

Sanitary RTD Without Protection Sheath-Rhs70 Series

Sanitary RTD Without Protection Sheath-Rhs70 Series
  • Sanitary RTD Without Protection Sheath-Rhs70 Series
Ask For Price
Product Price :Get Latest Price
Product Brochure

Product Details:

Minimum Order Quantity5 Piece
Model NumberRHS70 Series
Pressure Rangeup to 40 bar
ColorSilver
BrandRadix
MaterialStainless Steel
Degree of protectionIP68

  • RTD with SMS connection
  • Offered with Sanitary SMS Connection with / without male part and gasket
  • SS316L material as standard for wetted parts
  • Reduced tip design for quick response & to minimize flow restrictions
  • Surface finishing Ra ? 0.6 ?m as standard. Consult sales for better finish
Request
Callback


Additional Information:

  • Item Code: RHS70Series
  • Pay Mode Terms: T/T (Bank Transfer)
  • Port of Dispatch: Navi Mumbai
Yes! I am Interested

Sanitary RTD Sensors with Tri Clover Connection

Sanitary RTD Sensors with Tri Clover Connection
  • Sanitary RTD Sensors with Tri Clover Connection
Ask For Price
Product Price :Get Latest Price

Product Details:

Minimum Order Quantity1 Piece(s)
Model Name/NumberRH607
Connection0.5" / 1" / 1.5"/ 2" Triclover connections
TerminationWeatherproof Die cast aluminum head with threaded cap and chain
Element Type2, 3 or 4-wire platinum element
Assembly typeSimplex or Duplex assembly
Temperature-50 to 250C range
Wetted PartsSS316L wetted parts

Sanitary RTD Sensors With Tri Clover Connection - Head Type

Sanitary RTD sensors with tri clover connections and a head type terminations, are built for food, dairy, beverage, pharmaceutical and chemical industries, where maintenance of hygiene is critical in order to prevent contamination. Tri clover connections offers a clean and hygienic connection, designed to be clean in place (CIP). It is constructed to have no exposed thread connections and no abrupt changes in the structure, thereby preventing any contaminant buildup.Triclover connections are made of SS316L, built in 1.5”, 1” and 0.5 “ sizes. As the sheath does not bend, a sheath length greater than 300 mm is not recommended. The sheath terminates into a die cast, weatherproof aluminium head. The termination head is also available in a range of other materials. The sensor measure temperatures between -50 and 250°C. Its 2, 3 or 4 wire Pt100 RTD element can be constructed in single or dual assembly in Class A/Class B as per the IEC 751 standard for RTD sensors. The terminal head of the RTD sensors has a standard 1/2” BSP (F) single cable entry and a single compression cable gland.

Optional : Mounting Clamp and GasketDual cable entries and double compression cable glands are optional.Head-mounted transmittersConnecting Cables
Request
Callback


Additional Information:

  • Item Code: RH607
Yes! I am Interested

Sanitary RTD Sensors With Ingold Port

Sanitary RTD Sensors With Ingold Port
  • Sanitary RTD Sensors With Ingold Port
Ask For Price
Product Price :Get Latest Price

Product Details:

Minimum Order Quantity1 Piece(s)
BrandRadix
Model Name/NumberRHW604
TerminationWeatherproof Die cast aluminum head with threaded cap and chain
Element Type2, 3 or 4-wire platinum element in simplex or duplex assembly
Temperature-50 to 200 C range
Wetted PartsSS316L wetted parts
Surface FinishBetter than 0.6 micron
Sheath Diameter6 mm / 8 mm sheath diameter
Locking Nut3/4" BSP(F) /11/4" BSP(F) Stainless steel locking nut

Sanitary RTD sensors with ingold port are designed to be used in sterilizers, bio-reactors , food, beverage, dairy, pharmaceuticals and chemical industries, where hygiene takes top priority. The ingold port fitting offers a clean instrumentation mounting without compromising on the ease-of-use of a removable sensor. In gold port connections are bore cylinders that are welded to tanks into which plugs with O-ring seals are installed. This design has the flexibility to specify the O-ring location to minimize the “dead” space, which allows a clean installation. The ingold solution is ideal for sanitary vessels and fermentation applications. The RTD sensor is built with SS316L sheath. As the sheath does not bend, a sheath length greater than 300 mm is not recommended. The sheath terminates into a die cast, weatherproof aluminium head. The RTD sensors measure temperatures between -50 and 200°C. Its 3 wire Pt100 RTD element can be constructed in single or dual assembly in Class A/Class B as per the IEC 751 standard for RTD sensors. The terminal head of the RTD sensors has a standard 1/2” BSP (F) single cable entry and a single compression cable gland with the option of dual cable entry and double compression glands. Stainless steel terminal heads or transition joint assemblies can also be constructed.

Request
Callback


Additional Information:

  • Item Code: RHW604
Yes! I am Interested

Sanitary RTD Sensors With Female Nut

Sanitary RTD Sensors With Female Nut
  • Sanitary RTD Sensors With Female Nut
Ask For Price
Product Price :Get Latest Price

Product Details:

Minimum Order Quantity1 Piece(s)
BrandRadix
Model Name/NumberRHW601
TerminationWeatherproof Die cast aluminum head with threaded cap and chain
Element Type2, 3 or 4-wire platinum element in simplex or duplex assembly
Temperature-50 to 250C range
ConnectionsFemale process connections
Wetted PartsSS316L wetted parts
Cable Entry1/2" BSP (F) single cable entry with single compression gland

Sanitary RTD sensors with threaded female nuts are built for dairy, beverage, food, pharmaceutical and chemical industries, where maintenance of hygiene is critical in order to prevent contamination. The female nut is designed, so that no thread is exposed, thereby preventing any contaminant buildup.

Its threaded female nut is made of SS316L grade material. The RTD sensor is built with SS316L sheath. As the sheath does not bend, a sheath length greater than 300 mm is not recommended. The sheath terminates into a die cast, weatherproof aluminium head. The RTD sensors measure temperatures between -50 and 250°C. Its 2, 3 or 4 wire Pt100 RTD element can be constructed in single or dual assembly in Class A/Class B as per the IEC 751 standard for RTD sensors. The terminal head of the RTD sensors has a standard 1/2” BSP (F) single cable entry and a single compression cable gland with the option of dual cable entry and double compression glands.
Optional :Dual cable entries and double compression cable glands are optional.Head mounted transmittersConnecting Cables
Request
Callback


Additional Information:

  • Item Code: RHW601
Yes! I am Interested

Flameproof RTD Sensors - with Sanitary Fittings

Flameproof RTD Sensors - with Sanitary Fittings
  • Flameproof RTD Sensors - with Sanitary Fittings
Ask For Price
Product Price :Get Latest Price

Product Details:

Minimum Order Quantity1 Piece(s)
Model Name/NumberRHF607
BrandRadix
ConnectionThreaded / Flanged process connections
Temperature-50 to 250 C range
Sheath MaterialSS
Sheath Material GradeSS316L Sheath
Certified ForGas groups I, IIA and IIB (IIC optional)

Flameproof die cast aluminum head can also be available with sanitary fitting.Optional heads include cast-iron, SS316 and SS304. The standard head for Flameproof RTD sensors is certified flameproof for gas groups I, IIA and IIB. An assembly certified for gas group IIC (Hydrogen) can also be constructed.
Request
Callback


Additional Information:

  • Item Code: RHF607
Yes! I am Interested
X

Explore More Product

View All Product


Reach Us
Adwait Bangar (Manager)
Radix Electrosystems Private Limited
A566, TTC Industrial Area, MIDC, Mahape
Airoli, Navi Mumbai - 400710, Thane, Maharashtra, India


Call Us


Send E-mail