Call 08048600052 98% Response Rate

Send Email

Autoclave RTD Sensors

Our product range includes a wide range of pt100 type rac240 rtd for autoclave by radix., rac243 temperature probe with teflon insulated cable, rac240 rtd sensor for autoclave by radix, rac240 with leakproof assembly by radix, rtd probes for autoclave with class aa (1/3 din) accuracy. and radix rtd sensor rac251 for continuous use..

PT100 type RAC240 RTD for Autoclave by Radix.

PT100 type RAC240 RTD for Autoclave by Radix.
  • PT100 type RAC240 RTD for Autoclave by Radix.
  • PT100 type RAC240 RTD for Autoclave by Radix.
  • PT100 type RAC240 RTD for Autoclave by Radix.
Get Best Quote
Get Latest Price

Product Brochure

Product Details:
TypePT100
AccuracyClass AA (1/3DIN) as per IEC 60751
Model Name/NumberRAC240
Usage/ApplicationTemperature Measurement
BrandRadix
Material GradeSS316
Sheath length70 mm (2.75")
Diameter Range5 mm (0.19")
TerminationTeflon insulated, Silicon rubber jacket cable
Cable Length5 meters / 10 meters
Temperature Range0 to 150 DegreeC (32 to 302 DegreeF)
Country of OriginMade in India
  • Type: Pt100, 3-wire/4-wire to IEC 60751
  • Accuracy: Class AA (1/3 DIN)
  • No. of elements: Simplex/Duplex
  • Range: 0 to 150°C (32 to 302°F)
  • Sheath material: SS316L (1.4404)
  • Sheath diameter: 5 mm (0.19")
  • Sheath length (SL): 70 mm (2.75")
  • Cable type: Teflon insulated, Silicon rubber jacketed cable
  • Termination: Teflon insulated cable
  • Cable length (CL): 5/10 meters
  • Mounting bush: Included
Yes! I am InterestedRequest A Callback

RAC243 Temperature probe with Teflon insulated cable

RAC243 Temperature probe with Teflon insulated cable
  • RAC243 Temperature probe with Teflon insulated cable
  • RAC243 Temperature probe with Teflon insulated cable
  • RAC243 Temperature probe with Teflon insulated cable
Get Best Quote
Get Latest Price

Product Brochure

Product Details:
TypePT100
Model Name/NumberRAC243
BrandRadix
Sheath length50 mm (standard), 100 mm
Cable TypeTeflon insulated cable
Temperature (Deg. Celsius)0 to 150 DegreeC (32 to 302 DegreeF)
Country of OriginMade in India
Wire type3-wire/4-wire
Sheath diameter4 mm for simplex, 6 mm for duplex
Sheath materialSS316L (1.4404)
  • Type: Pt100, 3-wire/4-wire to IEC 60751
  • Accuracy: Class A (1/2 DIN)/Class AA (1/3 DIN)
  • No. of elements: Simplex/Duplex
  • Range: 0 to 150°C (32 to 302°F)
  • Sheath material: SS316L (1.4404)
  • Sheath diameter: 4 mm for simplex, 6 mm for duplex
  • Sheath length (SL): 50 mm (standard), 100 mm
  • Cable type: Teflon insulated cable
  • Cable length (CL): 3/5/10 meters


Additional Information:

  • Port of Dispatch: Mumbai, India
Yes! I am InterestedRequest A Callback

RAC240 RTD Sensor for Autoclave by Radix

RAC240 RTD Sensor for Autoclave by Radix
  • RAC240 RTD Sensor for Autoclave by Radix
  • RAC240 RTD Sensor for Autoclave by Radix
  • RAC240 RTD Sensor for Autoclave by Radix
Get Best Quote
Get Latest Price

Product Brochure

Product Details:
TypePT100
Sheath length70 mm (2.75")
Sheath Diameter5 mm (0.19")
Sheath MaterialSS316L (1.4404)
Model Name/NumberRAC240
Usage/ApplicationTemperature measurement
BrandRadix
Country of OriginMade in India
TerminationTeflon insulated, Silicon rubber jacketed cable
Type: Pt100, 3-wire/4-wire to IEC 60751
Accuracy: Class AA (1/3 DIN)
No. of elements: Simplex/Duplex
Range: 0 to 150°C (32 to 302°F)
Sheath material: SS316L (1.4404)
Sheath diameter: 5 mm (0.19")
Sheath length (SL): 70 mm (2.75")
Cable type: Teflon insulated, Silicon rubber jacketed cable
Termination: Teflon insulated cable
Cable length (CL): 5/10 meters
Mounting bush: Included
Yes! I am InterestedRequest A Callback

RAC240 with leakproof assembly by Radix

RAC240 with leakproof assembly by Radix
  • RAC240 with leakproof assembly by Radix
  • RAC240 with leakproof assembly by Radix
  • RAC240 with leakproof assembly by Radix
Get Best Quote
Get Latest Price

Product Brochure

Product Details:
TypePT100
Temperature Range-50 to 250 deg C
Termination TypeJack
Shear Lenght70 mm (2.75")
Shear Diameter5 mm(0.19")
Shear MaterialSS316L
Model Name/NumberRAC240
Country of OriginIndia
Cable TypeTeflon Insulated , Silicon Rubber
Type: Pt100, 3-wire/4-wire to IEC 60751
Accuracy: Class AA (1/3 DIN)
No. of elements: Simplex/Duplex
Range: 0 to 150°C (32 to 302°F)
Sheath material: SS316L (1.4404)
Sheath diameter: 5 mm (0.19")
Sheath length (SL): 70 mm (2.75")
Cable type: Teflon insulated, Silicon rubber jacketed cable
Termination: Teflon insulated cable
Cable length (CL): 5/10 meters
Mounting bush: Included
Yes! I am InterestedRequest A Callback

RTD probes for Autoclave with Class AA (1/3 DIN) accuracy.

RTD probes for Autoclave with Class AA (1/3 DIN) accuracy.
  • RTD probes for Autoclave with Class AA (1/3 DIN) accuracy.
  • RTD probes for Autoclave with Class AA (1/3 DIN) accuracy.
  • RTD probes for Autoclave with Class AA (1/3 DIN) accuracy.
Get Best Quote
Get Latest Price

Product Brochure

Product Details:
TypePT100
Temperature Range-50 to 250 deg C
Termination TypeJack
Sheath length70 mm (2.75")
Sheath Diameter5 mm (0.19")
Sheath materialSS316L (1.4404)
Country of OriginMade in India
Model name/numberRAC240
TerminationTeflon insulated, Silicon rubber jacketed cable
Type: Pt100, 3-wire/4-wire to IEC 60751
Accuracy: Class AA (1/3 DIN)
No. of elements: Simplex/Duplex
Range: 0 to 150°C (32 to 302°F)
Sheath material: SS316L (1.4404)
Sheath diameter: 5 mm (0.19")
Sheath length (SL): 70 mm (2.75")
Cable type: Teflon insulated, Silicon rubber jacketed cable
Termination: Teflon insulated cable
Cable length (CL): 5/10 meters
Mounting bush: Included
Yes! I am InterestedRequest A Callback

Radix RTD sensor RAC251 For continuous use.

Radix RTD sensor RAC251 For continuous use.
  • Radix RTD sensor RAC251 For continuous use.
  • Radix RTD sensor RAC251 For continuous use.
  • Radix RTD sensor RAC251 For continuous use.
Get Best Quote
Get Latest Price

Product Brochure

Product Details:
TypePT100
Sensor Connection Wiring3 Wire
Material GradeSS316
Sheath length50 mm
Cable TypeTeflon insulated cable
Model Name/NumberRAC251
Sheath diameter6 mm
Country of OriginMade in India
No. of elementsSimplex/Duplex
Type: Pt100, 3-wire to IEC 60751
Accuracy:Class AA (1/3 DIN)
No. of elements: Simplex/Duplex
Range: 0 to 150°C (32 to 302°F)
Sheath material: SS316L (1.4404)
Sheath diameter: 6 mm
Sheath length (SL): 50 mm
Cable type: Teflon insulated cable
Cable length (CL): 5/10 meters
Mounting bush: Included
Yes! I am InterestedRequest A Callback

Radix RAC243 RTD Probe with Cable length 3/5/10 meters.

Radix RAC243 RTD Probe with Cable length 3/5/10 meters.
  • Radix RAC243 RTD Probe with Cable length 3/5/10 meters.
  • Radix RAC243 RTD Probe with Cable length 3/5/10 meters.
  • Radix RAC243 RTD Probe with Cable length 3/5/10 meters.
  • Radix RAC243 RTD Probe with Cable length 3/5/10 meters.
Get Best Quote
Get Latest Price

Product Brochure

Product Details:
TypePT100
Sheath length50 mm (standard), 100 mm
Wire type3-wire/4-wire
Cable typeTeflon insulated cable
Sheath diameter4 mm for simplex, 6 mm for duplex
Model Name/NumberRAC243
Country of OriginMade in India
Sheath materialSS316L (1.4404)
Temp Range0 to 150 DegreeC (32 to 302 DegreeF)
BrandRadix
  • Type: Pt100, 3-wire/4-wire to IEC 60751
  • Accuracy: Class A (1/2 DIN)/Class AA (1/3 DIN)
  • No. of elements: Simplex/Duplex
  • Range: 0 to 150°C (32 to 302°F)
  • Sheath material: SS316L (1.4404)
  • Sheath diameter: 4 mm for simplex, 6 mm for duplex
  • Sheath length (SL): 50 mm (standard), 100 mm
  • Cable type: Teflon insulated cable
  • Cable length (CL): 3/5/10 meters
Yes! I am InterestedRequest A Callback

50mm Standard Sheath length RTD sensor for Autoclave.

50mm Standard Sheath length RTD sensor for Autoclave.
  • 50mm Standard Sheath length RTD sensor for Autoclave.
  • 50mm Standard Sheath length RTD sensor for Autoclave.
  • 50mm Standard Sheath length RTD sensor for Autoclave.
Get Best Quote
Get Latest Price

Product Brochure

Product Details:
TypePT100
Sensor Connection Wiring3 Wire
Material GradeSS316
Sheath length50 mm
Cable typeTeflon insulated cable
Sheath diameter6 mm
Sheath materialSS316L (1.4404)
Country of OriginMade in India
No. of elementsSimplex/Duplex
Model Name/NumberRAC251
Type: Pt100, 3-wire to IEC 60751
Accuracy:Class AA (1/3 DIN)
No. of elements: Simplex/Duplex
Range: 0 to 150°C (32 to 302°F)
Sheath material: SS316L (1.4404)
Sheath diameter: 6 mm
Sheath length (SL): 50 mm
Cable type: Teflon insulated cable
Cable length (CL): 5/10 meters
Mounting bush: Included
Yes! I am InterestedRequest A Callback

Radix RAC251 RTD Probe with Cable length 5/10 meters.

Radix RAC251 RTD Probe with Cable length 5/10 meters.
  • Radix RAC251 RTD Probe with Cable length 5/10 meters.
  • Radix RAC251 RTD Probe with Cable length 5/10 meters.
  • Radix RAC251 RTD Probe with Cable length 5/10 meters.
Get Best Quote
Get Latest Price

Product Brochure

Product Details:
TypePT100
Sensor Connection Wiring3 Wire
Material GradeSS316
Sheath length50 mm
Mounting bushIncluded
Cable typeTeflon insulated cable
Sheath diameter6 mm
Sheath materialSS316L (1.4404)
Model Name/NumberRAC251
Country of OriginMade in India
No. of elementsSimplex/Duplex
Type: Pt100, 3-wire to IEC 60751
Accuracy:Class AA (1/3 DIN)
No. of elements: Simplex/Duplex
Range: 0 to 150°C (32 to 302°F)
Sheath material: SS316L (1.4404)
Sheath diameter: 6 mm
Sheath length (SL): 50 mm
Cable type: Teflon insulated cable
Cable length (CL): 5/10 meters
Mounting bush: Included
Yes! I am InterestedRequest A Callback

RAC243 designed with Simplex/Duplex element.

RAC243 designed with Simplex/Duplex element.
  • RAC243 designed with Simplex/Duplex element.
  • RAC243 designed with Simplex/Duplex element.
  • RAC243 designed with Simplex/Duplex element.
  • RAC243 designed with Simplex/Duplex element.
Get Best Quote
Get Latest Price

Product Brochure

Product Details:
TypePT100
Sheath length50 mm (standard), 100 mm
Wire type3-wire/4-wire
Cable typeTeflon insulated cable
Sheath diameter4 mm for simplex, 6 mm for duplex
Model Name/NumberRAC243
Country of OriginMade in India
Sheath materialSS316L (1.4404)
Temp Range0 to 150 DegreeC (32 to 302 DegreeF)
BrandRadix
  • Type: Pt100, 3-wire/4-wire to IEC 60751
  • Accuracy: Class A (1/2 DIN)/Class AA (1/3 DIN)
  • No. of elements: Simplex/Duplex
  • Range: 0 to 150°C (32 to 302°F)
  • Sheath material: SS316L (1.4404)
  • Sheath diameter: 4 mm for simplex, 6 mm for duplex
  • Sheath length (SL): 50 mm (standard), 100 mm
  • Cable type: Teflon insulated cable
  • Cable length (CL): 3/5/10 meters
Yes! I am InterestedRequest A Callback

50mm Standard Sheath length RAC243 RTD sensor for Autoclave Validation

50mm Standard Sheath length RAC243 RTD sensor for Autoclave Validation
  • 50mm Standard Sheath length RAC243 RTD sensor for Autoclave Validation
  • 50mm Standard Sheath length RAC243 RTD sensor for Autoclave Validation
  • 50mm Standard Sheath length RAC243 RTD sensor for Autoclave Validation
  • 50mm Standard Sheath length RAC243 RTD sensor for Autoclave Validation
Get Best Quote
Get Latest Price

Product Brochure

Product Details:
TypePT100
Sheath length50 mm (standard), 100 mm
Wire type3-wire/4-wire
Cable typeTeflon insulated cable
Sheath diameter4 mm for simplex, 6 mm for duplex
Model Name/NumberRAC243
Country of OriginMade in India
Sheath materialSS316L (1.4404)
Temp Range0 to 150 DegreeC (32 to 302 DegreeF)
  • Type: Pt100, 3-wire/4-wire to IEC 60751
  • Accuracy: Class A (1/2 DIN)/Class AA (1/3 DIN)
  • No. of elements: Simplex/Duplex
  • Range: 0 to 150°C (32 to 302°F)
  • Sheath material: SS316L (1.4404)
  • Sheath diameter: 4 mm for simplex, 6 mm for duplex
  • Sheath length (SL): 50 mm (standard), 100 mm
  • Cable type: Teflon insulated cable
  • Cable length (CL): 3/5/10 meters
Yes! I am InterestedRequest A Callback

RAC242 Angular Autoclave RTD sensor by Radix.

RAC242 Angular Autoclave RTD sensor by Radix.
  • RAC242 Angular Autoclave RTD sensor by Radix.
  • RAC242 Angular Autoclave RTD sensor by Radix.
  • RAC242 Angular Autoclave RTD sensor by Radix.
Get Best Quote
Get Latest Price

Product Brochure

Product Details:
TypePT100
Sensor Connection Wiring4 Wire
Sheath length150 mm
Cable typeTeflon insulated cable
Cable length (CL)5/10 meters
Sheath diameter3 / 3.17 mm
Sheath materialSS316L (1.4404)
Temp range0 to 180 DegreeC
No. of elementsSimplex (One), Duplex (Two)
Model Name/NumberRAC242
Country of OriginMade in India
BrandRadix
Type: Pt100, 4-wire to IEC 60751
Accuracy:Class AA (1/3 DIN)
No. of elements:Simplex (One), Duplex (Two)
Range: 0 to 180°C
Sheath material: SS316L (1.4404)
Sheath diameter: 3 / 3.17 mm
Sheath length (SL): 150 mm
Cable type: Teflon insulated cable
Cable length (CL): 5/10 meters
Yes! I am InterestedRequest A Callback

Radix RAC242 designed with Simplex/Duplex element.

Radix RAC242 designed with Simplex/Duplex element.
  • Radix RAC242 designed with Simplex/Duplex element.
  • Radix RAC242 designed with Simplex/Duplex element.
  • Radix RAC242 designed with Simplex/Duplex element.
Get Best Quote
Get Latest Price

Product Brochure

Product Details:
TypePT100
Sensor Connection Wiring4 Wire
Sheath length150 mm
Cable typeTeflon insulated cable
Cable length (CL)5/10 meters
Sheath diameterSS316L (1.4404)
Temp range0 to 180 DegreeC
No. of elementsSimplex (One), Duplex (Two)
Model Name/NumberRAC242
Country of OriginMade in India
BrandRadix
Type: Pt100, 4-wire to IEC 60751
Accuracy:Class AA (1/3 DIN)
No. of elements:Simplex (One), Duplex (Two)
Range: 0 to 180°C
Sheath material: SS316L (1.4404)
Sheath diameter: 3 / 3.17 mm
Sheath length (SL): 150 mm
Cable type: Teflon insulated cable
Cable length (CL): 5/10 meters
Yes! I am InterestedRequest A Callback

Probe type RTD RAC242 with Cable length 5/10 meters.

Probe type RTD RAC242 with Cable length 5/10 meters.
  • Probe type RTD RAC242 with Cable length 5/10 meters.
  • Probe type RTD RAC242 with Cable length 5/10 meters.
  • Probe type RTD RAC242 with Cable length 5/10 meters.
Get Best Quote
Get Latest Price

Product Brochure

Product Details:
TypePT100
Sheath length150 mm
Cable typeTeflon insulated cable
Cable length (CL)5/10 meters
Sheath diameter3 / 3.17 mm
Sheath materialSS316L (1.4404)
Temp range0 to 180 DegreeC
No. of elementsSimplex (One), Duplex (Two)
Model Name/NumberRAC242
Country of OriginMade in India
BrandRadix
Type: Pt100, 4-wire to IEC 60751
Accuracy:Class AA (1/3 DIN)
No. of elements:Simplex (One), Duplex (Two)
Range: 0 to 180°C
Sheath material: SS316L (1.4404)
Sheath diameter: 3 / 3.17 mm
Sheath length (SL): 150 mm
Cable type: Teflon insulated cable
Cable length (CL): 5/10 meters
Yes! I am InterestedRequest A Callback

Radix RAC232 Straight tube RTD sensor

Radix RAC232 Straight tube RTD sensor
  • Radix RAC232 Straight tube RTD sensor
  • Radix RAC232 Straight tube RTD sensor
  • Radix RAC232 Straight tube RTD sensor
Get Best Quote
Get Latest Price

Product Brochure

Product Details:
TypePT100
Sensor Connection Wiring4 Wire
Material GradeSS316
Sheath length150 mm
BrandRadix
Country of OriginMade in India
Model Name/NumberRAC232
Cable length (CL)5/10 meters
No. of elementsSimplex (One), Duplex (Two)
Sheath diameter3 / 3.17 mm
Temp Range0 to 180 DegreeC
  • Type: Pt100, 4-wire to IEC 60751
  • Accuracy:Class AA (1/3 DIN)
  • No. of elements:Simplex (One), Duplex (Two)
  • Range: 0 to 180°C
  • Sheath material: SS316L (1.4404)
  • Sheath diameter: 3 / 3.17 mm
  • Sheath length (SL): 150 mm
  • Cable type: Teflon insulated cable
  • Cable length (CL): 5/10 meters
Yes! I am InterestedRequest A Callback

Pin type termination RAC232 probe type RTD sensor

Pin type termination RAC232 probe type RTD sensor
  • Pin type termination RAC232 probe type RTD sensor
  • Pin type termination RAC232 probe type RTD sensor
  • Pin type termination RAC232 probe type RTD sensor
Get Best Quote
Get Latest Price

Product Brochure

Product Details:
TypePT100
Sensor Connection Wiring4 Wire
Material GradeSS316
Sheath length150 mm
BrandRadix
Country of OriginMade in India
Model Name/NumberRAC232
Cable length (CL)5/10 meters
No. of elementsSimplex (One), Duplex (Two)
Sheath diameter3 / 3.17 mm
Temp Range0 to 180 DegreeC
  • Type: Pt100, 4-wire to IEC 60751
  • Accuracy:Class AA (1/3 DIN)
  • No. of elements:Simplex (One), Duplex (Two)
  • Range: 0 to 180°C
  • Sheath material: SS316L (1.4404)
  • Sheath diameter: 3 / 3.17 mm
  • Sheath length (SL): 150 mm
  • Cable type: Teflon insulated cable
  • Cable length (CL): 5/10 meters
Yes! I am InterestedRequest A Callback

Probe type RAC251 RTD for Autoclave with Teflon jacketed cable.

Probe type RAC251 RTD for Autoclave with Teflon jacketed cable.
  • Probe type RAC251 RTD for Autoclave with Teflon jacketed cable.
  • Probe type RAC251 RTD for Autoclave with Teflon jacketed cable.
  • Probe type RAC251 RTD for Autoclave with Teflon jacketed cable.
Get Best Quote
Get Latest Price

Product Brochure

Product Details:
TypePT100
Sensor Connection Wiring3 Wire
Material GradeSS316
Sheath length50 mm
Mounting bushIncluded
Cable typeTeflon insulated cable
Sheath diameter6 mm
Sheath materialSS316L (1.4404)
Model Name/NumberRAC251
No. of elementsSimplex/Duplex
Country of OriginMade in India
Type: Pt100, 3-wire to IEC 60751
Accuracy:Class AA (1/3 DIN)
No. of elements: Simplex/Duplex
Range: 0 to 150°C (32 to 302°F)
Sheath material: SS316L (1.4404)
Sheath diameter: 6 mm
Sheath length (SL): 50 mm
Cable type: Teflon insulated cable
Cable length (CL): 5/10 meters
Mounting bush: Included
Yes! I am InterestedRequest A Callback

Radix RAC232 RTD for autoclave upto Cable length 5/10 meters

Radix RAC232 RTD for autoclave upto Cable length 5/10 meters
  • Radix RAC232 RTD for autoclave upto Cable length 5/10 meters
  • Radix RAC232 RTD for autoclave upto Cable length 5/10 meters
  • Radix RAC232 RTD for autoclave upto Cable length 5/10 meters
Get Best Quote
Get Latest Price

Product Brochure

Product Details:
TypePT100
Sensor Connection Wiring4 Wire
Material GradeSS316
Sheath length150 mm
BrandRadix
Country of OriginMade in India
Model Name/NumberRAC232
Cable length (CL)5/10 meters
No. of elementsSimplex (One), Duplex (Two)
Sheath diameter3 / 3.17 mm
Temp Range0 to 180 DegreeC
  • Type: Pt100, 4-wire to IEC 60751
  • Accuracy:Class AA (1/3 DIN)
  • No. of elements:Simplex (One), Duplex (Two)
  • Range: 0 to 180°C
  • Sheath material: SS316L (1.4404)
  • Sheath diameter: 3 / 3.17 mm
  • Sheath length (SL): 150 mm
  • Cable type: Teflon insulated cable
  • Cable length (CL): 5/10 meters
Yes! I am InterestedRequest A Callback

Radix RAC243 Temperature sensor used for sterilization process application.

Radix RAC243 Temperature sensor used for sterilization process application.
  • Radix RAC243 Temperature sensor used for sterilization process application.
  • Radix RAC243 Temperature sensor used for sterilization process application.
  • Radix RAC243 Temperature sensor used for sterilization process application.
Get Best Quote
Get Latest Price

Product Brochure

Product Details:
Country of OriginMade in India
Sheath length50 mm (standard), 100 mm
Wire type3-wire/4-wire
Cable typeTeflon insulated cable
Sheath diameter4 mm for simplex, 6 mm for duplex
Model Name/NumberRAC243
Sheath materialSS316L (1.4404)
Temp Range0 to 150 DegreeC (32 to 302 DegreeF)
  • Type: Pt100, 3-wire/4-wire to IEC 60751
  • Accuracy: Class A (1/2 DIN)/Class AA (1/3 DIN)
  • No. of elements: Simplex/Duplex
  • Range: 0 to 150°C (32 to 302°F)
  • Sheath material: SS316L (1.4404)
  • Sheath diameter: 4 mm for simplex, 6 mm for duplex
  • Sheath length (SL): 50 mm (standard), 100 mm
  • Cable type: Teflon insulated cable
  • Cable length (CL): 3/5/10 meters
Yes! I am InterestedRequest A Callback

RTD For Continuous Use In Autoclave RAC244

RTD For Continuous Use In Autoclave RAC244
Get Best Quote
Get Latest Price

Product Brochure

Product Details:
AccuracyClass A as per IEC751
Usage/ApplicationIndustrial
BrandRadix
Model Name/NumberRAC244
Temperature Range0 to 150 DegreeC
Cable Length5 meters / 10 meters
TerminationTeflon insulated, Silicon rubber jacket cable
Sheath Length50mm (Standard), 75mm / 100mm (Optional)
Country of OriginMade in India
  • Pt-100, 3-wire, optional 4-wire 
  • Accuracy: Class A as per IEC751
  • Range 0 to 150°C 
  • Shealth Material: SS316L
  • Cable Length: 5 meters / 10 meters
Yes! I am InterestedRequest A Callback

RTD Sensor for Continuous Use in Autoclave

RTD Sensor for Continuous Use in Autoclave
Get Best Quote
Get Latest Price

Product Brochure

Product Details:
Usage/ApplicationIndustrial
BrandRadix
Model Name/NumberRAC241
Temperature (Deg. Celsius)0 to 150 DegreeC
Cable Length5 meters / 10 meters
TerminationTeflon insulated, Silicon rubber jacket cable
Cable TypeSilicone rubber jacketed cable
AccuracyClass AA (1/3DIN) as per IEC 60751
Model NumberRAC241
Sheath MocSS316L
Country of OriginMade in India
Specifically designed to withstand high pressure & temperature of the continuous sterilization process in autoclaves. Capable of measuring temperature upto 150°C. Completely sealed construction. As a result, the entire sensor assembly, including the probe and cables extending from the RTD, can be completely submerged in water without affecting accuracy or long-term stability
Yes! I am InterestedRequest A Callback
Product Price: Get Latest Price

Product Brochure

Product Details:
RTD Element MaterialPlatinum
AccuracyClass A
Temperature Range-40 to 450 deg C
Sensor Connection Wiring3 Wire
ApplicationPharmaceutical
Termination TypeTerminal Head Assembly
Process Connection TypeThreaded (NPT/BPT)
Material GradeSS310
BrandRadix
OptionsNABL calibration, Head mounted transmitter
Sensor ConfigurationDuplex
Temperature ranges from -50 to 400 °C (-58 to 752ºF)
Provided with various constructions
Wide range of terminal heads for different applications
Class A/AA accuracy
Available in different diameters as per suitability to various applications
Yes! I am InterestedRequest A Callback